GD_02 | Wet screed / heavy fill (loose or inserts )
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 61 44 0.40 90 330 -80
+ G Plasterboard 62 44 0.39 120 343 -78
+ RP Resilient profile 65 39 0.33 120 370 -74
+ SC Suspended ceiling 68 37 0.28 120 403 -72
+ SC / 2*G Suspended ceiling, double planked 73 35 0.28 120 415 -70
GD_01 | Wet screed / no or light fill
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 55 60 0.41 90 250 -83
+ G Plasterboard 56 60 0.40 120 263 -80
+ RP Resilient profile 58 54 0.33 120 290 -77
+ SC Suspended ceiling 60 50 0.29 120 323 -75
+ SC / 2*G Suspended ceiling, double planked 72 45 0.28 120 335 -72
DA_07 | Flat roof / wood terrace
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 38 62 0.14 60 427 -69
+ G Plasterboard 39 62 0.14 60 440 -66
+ RP Resilient profile 46 57 0.13 60 467 -63
+ SC Suspended ceiling 51 52 0.12 60 500 -61
+ SC / 2*G Suspended ceiling, double planked 58 46 0.12 90 512 -58
DA_06 | Flat roof / concrete blocks
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 55 49 0.12 60 487 -40
+ G Plasterboard 56 49 0.12 60 500 -38
+ RP Resilient profile 58 45 0.11 60 527 -34
+ SC Suspended ceiling 60 42 0.10 60 560 -32
+ SC / 2*G Suspended ceiling, double planked 70 39 0.10 90 572 -30
DA_05 | Flat roof / greening
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 47 - 0.14 60 417 -44
+ G Plasterboard 48 - 0.14 60 430 -42
+ RP Resilient profile 53 - 0.13 60 457 -39
+ SC Suspended ceiling 56 - 0.12 60 490 -36
+ SC / 2*G Suspended ceiling, double planked 62 - 0.12 90 502 -34
DA_04 | Flat roof / EPS
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 36 - 0.14 60 332 -44
+ G Plasterboard 37 - 0.14 60 345 -42
+ RP Resilient profile 45 - 0.13 60 372 -39
+ SC Suspended ceiling 51 - 0.13 60 405 -36
+ SC / 2*G Suspended ceiling, double planked 56 - 0.12 90 417 -34
DA_03 | Flat roof / mineral wool (or wood fiber)
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 44 - 0.16 60 332 -20
+ G Plasterboard 45 - 0.16 60 345 -17
+ RP Resilient profile 49 - 0.15 60 372 -14
+ SC Suspended ceiling 53 - 0.14 60 405 -12
+ SC / 2*G Suspended ceiling, double planked 57 - 0.14 90 417 -9
DA_02 | Steep roof / metal sheet
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 50 - 0.10 60 481 -33
+ G Plasterboard 51 - 0.10 60 494 -31
+ RP Resilient profile 52 - 0.10 60 521 -27
+ SC Suspended ceiling 55 - 0.09 60 554 -25
+ SC / 2*G Suspended ceiling, double planked 59 - 0.09 90 566 -22
DA_01 | Steep roof / tiles
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 50 - 0.14 60 504 -91
+ G Plasterboard 51 - 0.14 60 517 -89
+ RP Resilient profile 52 - 0.13 60 544 -85
+ SC Suspended ceiling 56 - 0.12 60 577 -83
+ SC / 2*G Suspended ceiling, double planked 62 - 0.12 90 589 -80
GD_09 | Carpet floor
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 35 62 0.56 90 175 -96
+ G Plasterboard 36 62 0.54 120 188 -94
+ RP Resilient profile 45 58 0.43 120 215 -90
+ SC Suspended ceiling 55 53 0.35 120 250 -87
+ SC / 2*G Suspended ceiling, double planked 57 48 0.35 120 260 -86
GD_08 | Double floor / TCC
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 61 47 0.32 90 468 -79
+ G Plasterboard 61 47 0.31 120 481 -78
+ RP Resilient profile 63 42 0.27 120 508 -73
+ SC Suspended ceiling 64 39 0.24 120 541 -70
+ SC / 2*G Suspended ceiling, double planked 78 37 0.24 120 553 -68
GD_07 | Wood planks / wood fiber system
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 53 64 0.25 90 280 -128
+ G Plasterboard 54 64 0.25 120 293 -125
+ RP Resilient profile 56 60 0.22 120 320 -122
+ SC Suspended ceiling 58 54 0.20 120 353 -119
+ SC / 2*G Suspended ceiling, double planked 70 48 0.20 120 365 -117
GD_06 | Dry screed / heavy fill (loose or inserts )
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 61 54 0.42 90 295 -91
+ G Plasterboard 62 54 0.41 120 308 -88
+ RP Resilient profile 64 50 0.34 120 335 -85
+ SC Suspended ceiling 65 46 0.29 120 368 -83
+ SC / 2*G Suspended ceiling, double planked 72 43 0.29 120 380 -80
GD_05 | Dry screed / no or light fill
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 55 61 0.42 90 215 -93
+ G Plasterboard 56 61 0.42 120 228 -91
+ RP Resilient profile 58 56 0.35 120 255 -88
+ SC Suspended ceiling 60 51 0.30 120 288 -85
+ SC / 2*G Suspended ceiling, double planked 70 46 0.29 120 300 -83
GD_04 | Wet screen / TCC / no fill
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 66 46 0.36 90 330 -65
+ G Plasterboard 67 46 0.36 120 343 -63
+ RP Resilient profile 69 40 0.30 120 370 -59
+ SC Suspended ceiling 72 38 0.26 120 403 -57
+ SC / 2*G Suspended ceiling, double planked 81 36 0.26 120 415 -55
GD_03 | Wet screed / bonded heavy fill (elastic or acoustic layer)
Sound Rw [dB]
Impact Ln,w [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 59 46 0.40 90 336 -72
+ G Plasterboard 60 46 0.39 120 349 -69
+ RP Resilient profile 62 41 0.32 120 376 -66
+ SC Suspended ceiling 68 39 0.28 120 409 -63
+ SC / 2*G Suspended ceiling, double planked 74 37 0.28 120 421 -61

Technical Approvals, Certificates and Eco-labels

We are there for you.

+44 (0) 20 3031 8070
General Business: office@klhuk.com
Project Enquiries: enquiry@klhuk.com

KLH UK Limited
23 Jacob Street
London SE1 2BG

We really wanted to say thank you to everyone who has been involved in getting us this far. We have been really excited to see the structure go up and the on-site team have done an amazing job. The CLT looks great.

Mary & Klaus Morris | Blackwood House

I would like to record that I have been very impressed with your work on site and the efficiency of your construction team. The finished product is exactly as expected and was completed ahead of programme. Thank you for the efforts of your team.

David Spooner | Construction Project Manager | Hastings Pier Charity

Mayfield School are delighted with the new buildings. Innovative use of space and light in the atrium areas and other specialist classrooms will enhance the possibilities available to our staff and students.
The Sixth Form is designed not only to give a real feature (Heller-Up staircase), but is also a practical and useable large space which can be used by the whole school for various activities. The new building and external areas have created a real ‘WOW’ factor for our community as a whole.

Allison Greenwood | Deputy Headteacher | Mayfield School

The Mayfield School Project was delivered on time and within budget. It is to an excellent quality of workmanship which surpassed the expectations of the client team and the end user. The building’s design is rational, durable and above all maintainable which will ensure that Mayfield School will continue to provide teaching excellence within the London Borough of Redbridge.

Steve McConaghy | Senior Construction Project Manager| London Borough of Redbridge

I am the HT of a school in the UK which has been constructed using CLT. I am tremendously impressed with the very calm and purposeful learning environment that has been created. The students are so proud of the building and the exposed CLT is a major factor in this as it gives a high-end quality finish not common in schools in the UK. The CLT construction method enabled the building process to be rapid which was a major factor in us moving in on time.

Keir Smith | Head Teacher | William Perkin C of E School

We are completely delighted with the CLT!!! It’s been very exciting seeing our project in the factory and then going-up on site so quickly.
We love the exposed CLT walls and the character it gives the interiors – we can’t wait to move in. I think that the KLH team has been excellent throughout, from first contact, through the quotation stage to shop-drawings and the on-site erection crew – everyone has been very professional and helpful at all times. It has been a pleasure working with you all – I would be very happy to use KLH again in the future.

Ruth Butler | Ruth Butler Architects | Convent Lane

There is a great ambience in occupying a CLT school and it generates interest and a positive atmosphere with students, staff and visitors. Would definitely recommend it to another school.

Head Teacher | City Academy, Norwich

We are there