Standard
component catalogue

Learn more

AW_02 | Ventilated facade panel
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 53 0.17 30 343 -46
+ G Plasterboard 54 0.17 60 355 -44
+ RP Resilient profile 58 0.16 60 382 -42
+ FF Facing formwork 60 0.14 90 418 -37
+ FF / 2*G Facing formwork, self supporting, double planked 66 0.14 90 428 -37
AW_01 | Ventilated timber facade
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 44 0.17 30 391 -89
+ G Plasterboard 45 0.17 60 403 -87
+ RP Resilient profile 52 0.16 60 430 -85
+ FF Facing formwork 55 0.14 90 463 -81
+ FF / 2*G Facing formwork, self supporting, double planked 63 0.14 90 476 -80
IW_09 | Two layer KLH® 3s 100
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 62 0.26 30 295 -112
+ G Plasterboard 64 0.25 60 320 -107
+ RP Resilient profile 68 0.22 60 347 -104
+ FF Facing formwork 69 0.20 60 380 -100
+ FF / 2*G Facing formwork, self supporting, double planked 73 0.19 60 390 -99
IW_08 | Facing formwork self supporting
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 60 0.43 30 185 -50
+ G Plasterboard 61 0.42 60 198 -48
+ RP Resilient profile 63 0.35 60 225 -43
+ FF Facing formwork 64 0.29 90 260 -38
+ FF / 2*G Facing formwork, self supporting, double planked 70 0.28 90 270 -40
IW_07 | Facing formwork CW-profiles
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 47 0.45 30 173 -51
+ G Plasterboard 48 0.44 60 185 -48
+ RP Resilient profile 50 0.36 60 215 -44
+ FF Facing formwork 52 0.30 90 250 -40
+ FF / 2*G Facing formwork, self supporting, double planked 62 0.29 90 260 -40
IW_06 | Facing formwork timber battens
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 41 0.45 30 163 -60
+ G Plasterboard 42 0.44 60 175 -57
+ RP Resilient profile 50 0.36 60 202 -54
+ FF Facing formwork 51 0.30 60 240 -49
+ FF / 2*G Facing formwork, self supporting, double planked 61 0.29 60 250 -49
IW_05 | Resilient profile
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 44 0.60 30 140 -54
+ G Plasterboard 45 0.59 60 152 -52
+ RP Resilient profile 48 0.45 60 179 -49
+ FF Facing formwork 50 0.36 60 215 -44
+ FF / 2*G Facing formwork, self supporting, double planked 63 0.35 60 225 -44
IW_04 | Cladded
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 34 0.87 30 113 -58
+ G Plasterboard 35 0.84 60 125 -55
+ RP Resilient profile 45 0.59 60 152 -52
+ FF Facing formwork 48 0.43 60 188 -48
+ FF / 2*G Facing formwork, self supporting, double planked 60 0.42 60 198 -48
IW_03 | KLH® 5s 160
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 39 0.63 30 160 -96
+ G Plasterboard 40 0.61 60 173 -94
+ RP Resilient profile 48 0.46 60 200 -90
+ FF Facing formwork 51 0.36 90 235 -86
+ FF / 2*G Facing formwork, self supporting, double planked 61 0.35 90 245 -86
IW_02 | KLH® 3s 100
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 33 0.91 30 100 -60
+ G Plasterboard 34 0.87 30 113 -58
+ RP Resilient profile 44 0.60 30 140 -54
+ FF Facing formwork 47 0.45 30 175 -50
+ FF / 2*G Facing formwork, self supporting, double planked 59 0.43 30 185 -50
IW_01 | KLH® 3s 60
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 29 1.32 - 60 -36
+ G Plasterboard 30 1.24 - 73 -34
+ RP Resilient profile 38 0.76 - 100 -30
+ FF Facing formwork 40 0.53 - 135 -26
+ FF / 2*G Facing formwork, self supporting, double planked 49 0.50 - 145 -26
AW_07 | ETICS - Hemp
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 54 0.18 30 311 -51
+ G Plasterboard 55 0.18 60 324 -48
+ RP Resilient profile 57 0.16 60 351 -45
+ FF Facing formwork 59 0.15 90 386 -41
+ FF / 2*G Facing formwork, self supporting, double planked 67 0.14 90 396 -41
AW_06 | ETICS - Wood fiber
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 39 0.17 30 311 -86
+ G Plasterboard 40 0.17 60 324 -84
+ RP Resilient profile 45 0.16 60 351 -81
+ FF Facing formwork 48 0.14 90 386 -77
+ FF / 2*G Facing formwork, self supporting, double planked 59 0.14 90 396 -77
AW_05 | ETICS - Mineral wool
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 41 0.15 30 311 -37
+ G Plasterboard 42 0.15 60 324 -34
+ RP Resilient profile 46 0.14 60 351 -31
+ FF Facing formwork 48 0.13 90 384 -28
+ FF / 2*G Facing formwork, self supporting, double planked 60 0.13 90 396 -27
AW_04 | ETICS - EPS
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 36 0.15 30 311 -39
+ G Plasterboard 37 0.15 60 324 -36
+ RP Resilient profile 45 0.14 60 351 -33
+ FF Facing formwork 47 0.13 90 384 -29
+ FF / 2*G Facing formwork, self supporting, double planked 56 0.13 90 396 -29
AW_03 | Plaster baseboard
Sound Rw [dB]
Thermal U [W/m2K]
Fire R*EI [min]
Thickness [mm]
Ecology [kg CO2 eq./m2]
KLH® visible 48 0.19 30 325 -53
+ G Plasterboard 49 0.18 60 338 -51
+ RP Resilient profile 54 0.17 60 365 -47
+ FF Facing formwork 55 0.15 90 398 -44
+ FF / 2*G Facing formwork, self supporting, double planked 63 0.15 90 410 -43

Technical Approvals, Certificates and Eco-labels

We are there for you.

+44 (0) 20 3031 8070
General Business: office@klhuk.com
Project Enquiries: enquiry@klhuk.com

KLH UK Limited
23 Jacob Street
London SE1 2BG

We really wanted to say thank you to everyone who has been involved in getting us this far. We have been really excited to see the structure go up and the on-site team have done an amazing job. The CLT looks great.

Mary & Klaus Morris | Blackwood House

I would like to record that I have been very impressed with your work on site and the efficiency of your construction team. The finished product is exactly as expected and was completed ahead of programme. Thank you for the efforts of your team.

David Spooner | Construction Project Manager | Hastings Pier Charity

Mayfield School are delighted with the new buildings. Innovative use of space and light in the atrium areas and other specialist classrooms will enhance the possibilities available to our staff and students.
The Sixth Form is designed not only to give a real feature (Heller-Up staircase), but is also a practical and useable large space which can be used by the whole school for various activities. The new building and external areas have created a real ‘WOW’ factor for our community as a whole.

Allison Greenwood | Deputy Headteacher | Mayfield School

The Mayfield School Project was delivered on time and within budget. It is to an excellent quality of workmanship which surpassed the expectations of the client team and the end user. The building’s design is rational, durable and above all maintainable which will ensure that Mayfield School will continue to provide teaching excellence within the London Borough of Redbridge.

Steve McConaghy | Senior Construction Project Manager| London Borough of Redbridge

I am the HT of a school in the UK which has been constructed using CLT. I am tremendously impressed with the very calm and purposeful learning environment that has been created. The students are so proud of the building and the exposed CLT is a major factor in this as it gives a high-end quality finish not common in schools in the UK. The CLT construction method enabled the building process to be rapid which was a major factor in us moving in on time.

Keir Smith | Head Teacher | William Perkin C of E School

We are completely delighted with the CLT!!! It’s been very exciting seeing our project in the factory and then going-up on site so quickly.
We love the exposed CLT walls and the character it gives the interiors – we can’t wait to move in. I think that the KLH team has been excellent throughout, from first contact, through the quotation stage to shop-drawings and the on-site erection crew – everyone has been very professional and helpful at all times. It has been a pleasure working with you all – I would be very happy to use KLH again in the future.

Ruth Butler | Ruth Butler Architects | Convent Lane

There is a great ambience in occupying a CLT school and it generates interest and a positive atmosphere with students, staff and visitors. Would definitely recommend it to another school.

Head Teacher | City Academy, Norwich

We are there
for you.